Handling robot battery (25.9V 30Ah)
CombinationICR18650-7S15P
Nominal Voltage
25.9V
Nominal Voltage
30Ah
Standard continuous discharge current
10A
Maximum continuous discharge current
20A
Working Temperature
charge0~45℃; discharge-20~60
Dimensions
MAX220*140*70mm
Cycle Life
500 times
Finished Product Resistance
≤150mΩ
Standard Weight
3.1Kg
Main Features
with communication function, electricity display, battery equalization, various protection functions
Output Mode
UL1007/14AWG length 60mmcustomizable

Design scheme of battery pack for handling robot

1) protection circuit board PCM):Mainly design against protection circuit board for rechargeable high capacity battery pack. Because of the chemical characteristics of lithium battery, in order to avoid burning, explosion etc. dangerous situation, must provide over charge, over discharge, short circuit, over current & over heat etc. protection function.

2protection ICProtection IC):Main protection function chip in design scheme, carry on-line constantly monitor on over charge, over discharge, over current, short circuit etc. function of battery cell. Ensure batter cell work within the scope of safety, stability, high efficiency.

3 over current protection chipPTC):Mainly design against secondary protection function. PTC can recover thermal fuse with dual function: over current protection & auto recovery. PTC inside battery cell can prevent the cell occurs high temperature discharge and un-safe large current.

4MOSFET chipMOSFET chip, on on-off action in protection circuit

5Packing of battery packplastic film

未标题-1.jpg.jpgApplication Fields:

Hanlding robot, Industrial robot etc.